LS-6004: 4 Channel Power Amplifier
Full power delivery. All channels driven simultaneously loaded 4 Ohms. Very useful and versatile multimode professional power amplifier, suited for large scale touring point source or line array systems.
Equally suited in less demanding bass applications. Very installation friendly and ideal for BI AMP stage monitoring systems or multi point theatre installations. Proprietary high efficiency FFA class D output stage coupled with high current switch mode supply enables high power delivery even in the harshest environment conditions.
Key Features:
- FFA Class D Technology
- Power supply soft start
- Power efficient and cool running
- Analog filter option card with limiter threshold and delay – ideal for stage monitor systems.
- High current switch mode power supply
- Side chain TCA clip limiter
- Rugged tour class aluminium construction
- Hand constructed and designed in England
- BI AMP Neutrik speakON outputs
- Signal link through
- Neutrik powerCON power input
- Lightweight 9KG
- 5 year factory warranty
LS-6004: 4 Channel Power Amplifier – Logic Systems Pro Audio
Technical Information:
GENERAL | SPECIFICATION |
---|---|
Power Rating: |
|
Gain | 32 dB |
THD | Typical 0.05 4 Ohm lKHz THD+N |
Frequency Response | 20Hz – 20 KHz |
Controls: | 40 Point Potentiometer per channel Power on switch |
Indicators: | Signal green = -20dB, Signal yellow = -3dB, Signal red = Clip, Signal red protect = Over current, Low AC mains or 3 sec. Mute on power up |
Cooling: | High CFM 80mm fan with proportional signal speed control. Rear to front airflow |
Load Protection | DC on output, side chain TCA clip limiter circuit |
Amplifier Protection | Short circuit, current overload, thermal shutdown, high frequency stability circuit |
Power Supply | 1 x Neutrik 20A powercon connector |
Power Requirement | 1 x 16A 240 VAC Circuit. Power range 185V-240VAC |
Dimensions | 2RU 19″ rack mount enclosure, H88mm x W483mm x D510mm. Depth includes integral rear rack support ears |
Weight | 9Kg |
CONNECTORS | SPECIFICATION |
---|---|
Audio Signal Inputs | Balanced Neutrik Female XLR input connected Pin 1 - GND, Pin 2 - Hot +, Pin 3 - Cold -. XLR Male signal throughput each channel |
Audio Signal Outputs | Neutrik speakon each channel. Channels 1 & 3 output speakon utilises 2+ & 2– connection to allow use of 4 core loudspeaker cable for bi amp loudspeaker system for example stage monitor system |